Q.1: What is coronary artery disease (CAD)?
A: Coronary artery disease is the most common type of heart disease. It happens when the arteries that supply blood to heart muscle(coronary arteries) become hardened and narrowed. This is due to build up of cholesterol and other material called plaque, on their inner walls. This build up is called atherosclerosis. This can lead to chest pain (angina) or a heart attack. Most heart attacks happen when a blood clot suddenly cuts off the hearts' blood supply, causing permanent heart damage. Over time, CAD can also weaken the heart muscle and contribute to heart failure and arrhythmias.
Q.2: What are the diagnostic modalities for CAD?
A: Various diagnostic modalities are increasingly used in the diagnosis of CAD which includes ECG, Echocardiography, coronary CT angiography, and cardiac single photon emission computed tomography (SPECT), and coronary angiography.
Q.3: What are the treatment modalities for CAD?
A: (i) Medical Management
(ii)Percutaneous Coronary Intervention- Angioplasty/Stenting
(iii)CABG(By pass surgery)
Depending on the extent and severity of involvement of coronary arteries and left ventricular (LV) function, clinician advises medical management or angioplasty or CABG.
Q.4: What are different types of percutaneous coronary intervention?
A: (i) Balloning(POBA)
(ii) Bare metal stent(BMS)implantation
(iii) Drug eluting stent(DES)implantation
Nowdays, almost all angioplasties are being performed using DES impantation.
Q.5: What is a coronary angiogram?
A: For definitive diagnosis of CAD to find out extent and severity of CAD and for its proper treatment,imaging of coronary arteries is done in cardiac cath lab.This is called as coronary angiography.
Q.6: What is angioplasty?
A: Angioplasty is a procedure that uses a balloon to open up blocked areas of your coronary arteries. It is performed to relieve some of the symptoms associated with CAD. It is also performed during a heart attack to prevent damage to the heart(Primary Angioplasty/stenting).
Q.7: What is the stent used for?
A: Stents are used for relieving obstruction in coronary arteries. The stent is a small metal-mesh tube that is implanted in the area of your coronary artery to help keep it open. Drug eluting stents in addition are designed to deliver medication to the artery. After the stenting procedure, the balloon is removed from your artery, but the stent will remain in your coronary artery.
Q.8: What are the different components of stents?
A: Drug eluting stent is made up of
i) Stent platform (Stainless steel, Cobalt chromium, Platinum chromium, etc.) and Balloon expandable delivery system
ii) Pharmacological agent (Everolimus, Sirolimus, etc.)
iii) Drug Carrier (eg. Polymer- Nonbiodegradable/Biodegradable)
These stents are available in various diameters and lengths . Stents from different manufacturers are available at our hospital. At the time of angioplasty, treating doctor discusses and informs the patient regarding the suitability of the stent according to his/her disease. The information about various kinds of stents along with their costs is available at our website.
Q.9: What is Primary angioplasty/stenting and its cost?
A: Primary angioplasty/stenting is an emergency procedure done during the time of ongoing heart attack.At our hospital,it is being done free of cost.
Q.10: How do I prepare for stenting?
A: Your doctor will give you a complete medical exam and provide you with detailed instructions. When you arrive at the hospital, you can expect to have a series of routine tests, such as an x-ray, electrocardiogram (EKG),echocardiography or blood tests etc.
Q.11: How can I get benefit from Government?
A: One can avail benefits under the Pradhan Mantri Jan Arogya Yojana as per the laid guidelines.
Q.12: How long will I have the stent?
A: Stents are designed to remain within your coronary artery permanently to provide lasting support.
Q.13: Will I feel the stent?
A: No. You will not feel the stent inside of you.
Q.14: Can the stent move?
A: Once the stent is opened and deployed at the inside wall of your coronary artery, it will remain in place permanently..
Q.15: How do coronary stents work?
A: Coronary stents are small, wire mesh tubes that help widen clogged arteries and restore adequate blood flow to the heart.
Q.16: How soon can I go back to work?
A: The majority of people return to work within a few days following a successful procedure.
Q.17: When can I resume my regular activities?
A: Your doctor will advise you on when it’s safe to resume your regular activities. Many patients can follow their normal routine with in a week after their successful angioplasty.
Q.18: Can I exercise and play sports with a stent?
A: Your doctor will tell you what physical activities are right for you and when you can safely resume them.
Q.19: Will my stent set off metal detectors?
A: No, your coronary stent will not trigger metal detector alarms and you can walk through them safely.
Q.20: How long should I take my medications after angioplasty/stenting?
A: The most important thing that you can do to minimize the risk of stent thrombosis(clot in coronary artery at the site of stent implantation) is to take the medications prescribed by your doctor prescribes. Do not stop taking these medicines specially blood thinners(Antiplatelets) until your cardiologist tells you to, even if you are feeling better.If you have a drug-eluting stent, you may need to take your medication for an extended period of time, perhaps a year or longer. Follow your doctor’s instructions exactly.
Q.21: Will I experience the symptoms of coronary artery disease again, such as chest pain?
A: It is possible that you will experience symptoms again, either because of a new blockage in the treated coronary artery or a new blockage in a different place. If you experience these symptoms, notify your doctor immediately.
Q.22: How will I know if my artery re-narrows?
A: Although the stents are intended to reduce restenosis, it is still possible for your artery to re-narrow. If this happens, you may experience symptoms similar to those experienced when you first noticed before your stent procedure. These symptoms may include chest pain or shortness of breath, especially during physical activity. If you experience pain, inform your doctor immediately.
Q.23: How can I help prevent a recurrence of symptoms?
A: While there is no sure way to prevent a recurrence of symptoms, you can reduce the risk through exercise, not smoking and eating a healthy diet. Ask your doctor about lifestyle changes you can make.
Q.24: What if I still have pain?
A: If you experience pain, immediately visit the emergency at our hospital .
S.No |
Date |
Particulars of Assets |
Name &address of supplier |
Bill No. & date |
Location of the Assets |
Remarks |
1 |
04/03/03 |
3M Steri-Vac (1) |
3M (I) Ltd. |
996/CNC/CARD/02-03 |
Cath Lab, CNC 01no. |
P-317/4 |
2 |
15/03/04 |
Anaesthesia Machine Excel-210E Astopad Plus Control (1) |
Rohanika Electronics |
100-79/CNC/CARD/02-03 |
Cath Lab, CNC 01no. |
P-331/4 |
3 |
31/05/05 |
Defibrillator LP-20 (1) |
Intstromedix |
100-34/CNC/CARD/04-05 |
.CT2 CCU CNC 01No. |
P-16/5 |
4 |
07/07/05 |
Programmable Stimulator BARD (1) |
Advanced Micronic Device |
100-31/CNC/CARD/04-05 |
Cath Lab. CNC 01No.
|
P-19/5 |
5 |
29/03/05 |
Dual Chamber Pacemaker (2) |
Saturn Med. System |
1211/CNC/CARD/04-05. |
Cath Lab, CNC 02nos. |
P-30/5 |
6 |
29/03/05 |
Single Chamber Pacemaker (10) |
Saturn Med. System |
1210/CNC/CARD/04-05 |
CT3 CNC 01no Cath Lab, CNC 02nos CT2 CCU CNC 02nos. CT6 CNC 02nos. |
P-31/5 |
7 |
27/05/06 |
Multiweigh (3-in-1) (Zeal) |
Globe Medical System |
1472/CNC/CARD/05-06 |
Cath Lab. CNC 02nos. (41) |
P-34/5 |
8 |
30/08/06 |
Transfusion Syringe Pumps (9) |
J.Mitra & Bros. |
100-48/CNC/CARD/05-06 |
Cath Lab, CNC 03nos CT2 CCU CNC 05nos. CT6 CNC 01nos |
P-36/5 |
9 |
28/10/06 |
Latest Advanced Tech. Ventilator (Servo) (1) |
Maquet Medical India (P) Ltd. |
100-51/CNC/CARD/05-06 |
CT2 CCU CNC 01no. CT6 CNC 01no |
P-39/5 |
11 |
17/10/06 |
IE33 Echocardiog-raphy System 01No. S.N.02RBWD |
Philips Electronics (I) Ltd. |
100-52/CNC/CARD/05-06 |
ECHO Lab. CNC 01no. |
P-40/5 |
12 |
09/10/06 |
TMT System (GE Model 2100) |
Wipro GE Medical System Ltd. |
100-74/CNC/CARD/05-06 |
TMT Lab. CNC 01no. |
P-41/5 |
13 |
12/04/07 |
Transport Monitor (M9000). |
Advanced Micronic Devices Ltd. |
1381/CNC/CARD/06-07 |
CT6 CNC 01no. 81 condemned |
P-43/5 |
14 |
29/05/07 |
External Defibrillator Med Aid 05Nos. |
Advanced Micronic Devices |
1380/CNC/CARD/06-07 |
CT3 CNC 01nos. CT6 CNC 01no. 3 condemned |
P-46/5 |
15 |
05/07/07 |
ACT200 Plus TM Automated Coagulation Timer 03Nos. |
J.Mitra & Bros. |
1379/CNC/CARD/06-07 |
Cath Lab, CNC 01no. CT2 CCU. CNC 01no CT3 CNC 01no. |
P-48/5 Through CTVS Department CNC |
16 |
09/08/07 |
Air Supply Unit for Horus Extend Unit 02Nos. |
Electrocare System & Services (P) Ltd. |
1476/CNC/CARD/06-07 |
CT2 CCU CNC 02nos. |
P-49/5 |
17 |
10/08/07 |
Ventilator 02Nos. |
Electrocare System & Services (P) Ltd. |
100-83/CNC/CARD/06-07 |
CT2 CCU CNC 02nos. |
P-50/5 |
18 |
16/07/07 |
Hemodynamic Recorder for Cath Lab I & II 02Nos. |
Wipro GE Healthcare |
100-61/CNC/CARD/06-07 |
Cath Lab CNC 02nos.(26, 27) |
P-51/5 |
19 |
26/09/07 |
Infusion Pumps 20Nos. |
J.Mitra & Bros. |
100-56/CNC/CARD/06-07 |
CT3 CNC 05nos Cath Lab CNC 05nos. CT2 CCU CNC 08nos. |
P-53/5 |
20 |
05/10/07 |
RF Generator & Infusion Pump 01No. |
Johnson & Johnson Ltd. |
100- 57/CNC/CARD/06-07 |
Cath Lab. CNC 01no. |
P-56/5 |
21 |
19/03/08 |
Intra Cardio Echo Catheter 01No. |
Siemens Ltd |
100-30/CARD/CNC/06-07 |
Echo Lab. CNC 01no. |
P-61/5 |
22 |
15/04/08 |
ECG Machine AT1 (Schiller) 02Nos. |
Schiller Healthcare (I) Pvt. Ltd. |
1114/CARD/CNC/07-08 |
ECG Lab CT6 CNC 2nos. (6, 7) |
P-63/5
|
23 |
04/09/2008 |
Bi Plane Cardiovascular Catheterisation Lab (Siemens) Lab I 01No. |
Siemens Ltd., 127, Henkestrasse, D-91052, Erlangen, Germany/Local-4A Ring Road, I.P. Estate, New Delhi-02 |
100-47/CNC/CARD/07-08 |
Cath Lab CNC 01No. HANDED OVER TO CARDIAC-RADIOLOGY |
P-65-66/5 |
24 |
04/09/2008 |
Local Accessories For Cath Lab S.O.100-47/CNC/CARD/07-08 |
Siemens,4A Ring Road, I.P. Estate, New Delhi-02 |
1196/CNC/CARD/07-08 |
Cath Lab CNC 01No LOCAL ACCESSRIES Lead glass 01no Servo stablizer150KVA 01no On-Line UPS 10KVA 01no. Personal Computer 03nos. Lead Aprons 10nos |
P-67/5 |
25 |
17/12/08 |
IVUS ILAB 240CART |
Boston Scientific International B.V. |
836/CARD/CNC/08-09 |
Cath Lab CNC 01No. |
P-69/5 |
26 |
29/12/08 |
VIVID 7 Dimension- Leadership 4D Cardiovascular Ultrasound System S.N. 11211V7L |
Wipro GE Heath Care (P) Ltd. |
100-9/CARD/CNC/08-09 |
Echo Lab CNC 01No. (4) |
P-70/5 |
27 |
30/03/09 |
TILT Table (Electric Operated) |
India Medico Instruments. |
1280/CNC/CARD/08-09 |
Tilt Lab . CNC(41) |
P-71/5 |
28 |
13/04/09 |
Anaesthesia Machine Prima SP 102 System |
Indian Surgical Equipment Co. (P) |
100-5/CARD/CNC/08-09 |
Cath Lab,CNC (33) |
P72/5 |
29 |
25/8/09 |
Blood Gas & Electrolyte Analyzer |
Rohit Surgical (P) Ltd. |
502/CNC/CARD/09-10 |
CT2CCU 02Nos Cath Lab 02Nos CT6 01No |
P-75/5 |
30 |
16/10/09 |
iE33 Intelligent Echocardiog-raphy Ultrasound System 01No. S.N. 034K85 |
Philips Electronics (I) Ltd. |
100-44/CNC/CARD/08-09 |
ECHO Lab. CNC 01no.(2) |
P-76/5 |
31 |
25/03/10 |
E.P.LAB |
St Jude Medical (I) Pvt.Ltd. |
1485/CNC/CARD/09-10 |
Cath Lab CNC 01No. (42) |
P-77/5 |
32 |
26/03/10 |
IABP(ARROW) |
Ace Medical |
1486/CNC/CARD/09-10 |
Cath Lab CNC 02 Nso.(7, 8) |
P-78/5 |
33 |
26/03/10 |
ECG Machine CP-200 |
BPLNoble Biomedicals Allen Welsch |
1400/CNC/CARD/09-10 |
ECG Lab OPD CNC 02Nos. (3,10) |
P-79/5 |
34 |
27/03/10 |
Basic Digital Copier (Size A-3) |
VSM Agencies Pvt. Ltd |
1490/CNC/CARD/09-10 |
Deptt. of CARD, CNC 01No. |
P-80/5 |
35 |
03/6/10 |
LP-15 Defib. Monitor with External Pacer
|
Medtronic Trading NL BV / Rohanika Electronics & Med |
100-60/CNC/CARD/09-10 |
Cath Lab CNC 01No.(15) Tilt Lab. CNC 01No.(42) 1 condemned ? |
P-81/5 |
36 |
06/10/10 |
Cardiac Monitors |
Philips Electronics
|
100-61/CNC/CARD/09-10 |
CT-6 Paed. CNC 16Nos. |
P-82/5 |
37 |
06/10/10 |
Ei33 2D Echocardiography Color Doppler System S.N. 03B4T9 |
Philips Electronics |
100-59/CNC/CARD/09-10 |
ECHO Lab. CNC 01No.(5) |
P83/5 |
38 |
20/01/11 |
FFR (Fractional Flow Reserve) |
Kox Med &Lab (P) Ltd. |
1010/CNC/CARD/10-11 |
Cath Lab CNC 01No. (25) |
P-84/5 |
39 |
10/03/11 |
ACT Plus (ACT-200) (Medtronic) |
J.Mitra & Bros |
1246/CNC/CARD/10-11 |
Cath Lab CNC 01No. |
P-85/5 |
40 |
25/05/10 |
Single Plane Cardiovascular Catheterisation with Digital Substraction Angiography (Wipro GE) Lab-III |
Wipro GE Healthcare (P) Ltd. |
100-40/CNC/CARD/09-10 |
Cath Lab CNC 01No
HANDED OVER TO CARDIAC-RADIOLOGY |
P-86/5 |
41 |
25/05/10
|
Local Accessories For S.O.100-40/CNC/CARD/09-10 |
Wipro GE Healthcare (P) Ltd. |
1510/CNC/CARD/09-10 |
Cath Lab CNC LOCAL ACCESSORIES Pressure Injector_Model Mark V Pro Vis Feom Medrad 01no 120 KVA UPS with 30 minutes backup 01no 150KVA Stablizer 01no. 10 Nos Lead Aprons with hanger 01no. Two way communication between Cathlab and control room 01no |
P-87/5 |
42 |
25/04/11
|
Portable 2D (CX50) Echocardiography Color Doppler System S.N. PHI42-02294 HW Rev.B.1 |
Philips Electronics (I) Ltd |
100-23/CNC/CARD/10-11 |
ECHO Lab. 1No(7) |
P-88/5 |
43 |
25/04/11
|
Ei33 2D ECHO Cardiography Color Doppler System S.N. B00PXJ HW Rev. G.1 |
Philips Electronics (I) Ltd |
100-24/CNC/CARD/10-11 |
ECHO Lab. 1No(3)
(Buy Back P143/4 HDI (ATL 9HDI 100-34/CNC/CARD/98-99 |
P-89/5 |
44 |
17/06/11 |
External Pacer with Defib. BeneHeart D6
|
Shenzhen Mindray Bio-Medical Electronics Co. Ltd. |
100-47/CNC/CARD/10-11 |
Cath Lab CNC 02Nos. CT2 CCU, CNC 02Nos CT3 CNC 02 Nos. |
P-90/5 |
45 |
12/07/11 |
Infant Warmer & Nursing Station
|
Phoenix Medical Systems (P) Ltd. |
244/CNC/CARD/ 11-12 |
CT6 02Nos. |
P-91/5 |
46 |
16/07/11 |
Computerized Stress Test System(TMT Machine)Model: X SCRIBE |
Compamedic Instruments (P) Ltd. |
100-38/CNC/CARD/ 10-11 |
TMT Lab., CNC 01No. |
P-92/5 |
47 |
09/08/11 |
Transport Incubator |
Medix I.C.S.A. |
100-39/ CNC/ CARD /10-11 |
CT6 01No. |
P-93/5 |
48 |
23/08/11 |
Hand Held ECHO. Mach. S.N. VH0092903H |
Wipro GE Healthcare |
100-40/ CNC/ CARD /10-11 |
Echo Lab. CNC, 01No. |
P-94/5
|
49 |
22/06/11
|
Single Plane Cardiovascular Catheterisation with Digital Substraction Angiography Lab. (Philips ) Lab-II |
Philips Electroncis (I) Ltd. |
100-25/CNC/CARD/10-11 |
Cath Lab CNC 01No
HANDED OVER TO CARDIAC-RADIOLOGY |
P-95/5
|
50 |
22/06/11 |
Local Accessories For S.O. 100-25/CNC/CARD/ 10-11 |
Philips Electroncis (I) Ltd. |
1293/CNC/CARD/ 10-11 LOCAL ACCESSORIES |
Cath Lab CNC LOCAL ACCESSORIES UPS for 120KVA with 30 mins back up 01No.
Difib. with External Pacer 01No.
Lead Apron 10Nos.
ACT Machine 01No.
P.C. with CD/DVD combo drive with Printer for CD viewing facility 02Nos. |
P-96/5 |
51 |
10/02/12 |
Cautery Machine (MEGAPOWER) Electro-surgical Generator |
Unicore Medical System (P) Ltd. |
1452/CNC/CARD/11-12 |
Cath Lab CNC 01No (32) |
P-97/5 |
52 |
01/03/12 |
Holter System
|
Schiller Healthcare |
1450/CNC/CARD/11-12 |
Holter lab. CNC 01No. 10 Nos-25-35 |
P-98/5 |
53 |
13/04/12 |
Terufusion Syringe Pump 220V 50Hz Safety Type
|
M/s J.Mitra & Bros. |
100-39CNC/CARD/11-12 |
Cath Lab CNC 03Nos. CT6 CNC 12Nos. CT3 CNC 12Nos. CT 2 CCU CNC 03Nos. |
P-99/5 |
54 |
13/08/12 |
Cardiac Monitors Intellivue MX 800 |
M/s Philips Electronics India Ltd. |
100-37/CNC/CARD/11-12 |
CT3 CNC 45Nos Cath Lab 3 Nos (38,39,40) |
P-100/5 |
55 |
17/11/12 |
ECG Machine ( BPL Model) Cardiart 9108 |
BPL Noble Biomedical |
1063/CNC/CARD/12-13 |
ECG Lab OPD , CNC 02 Nos (1,2) |
P-101/5 |
56 |
31/08/12 |
Shimadzu Motorized Mobile X-Ray Unit |
Shimadzu Medical (I) Pvt. Ltd. |
100-56/CNC/CR/11-12 |
01 No CT2 CNC 01 No CT6 CNC HANDED OVER TO CARDIAC-RADIOLOGY |
P-102/5 |
57 |
21/03/13 |
Infusion Pump |
Hansraj Nayyar Medical India |
1627/CNC/CARD/12-13 |
04Nos. Cath Lab CNC 02 Nos. CT2 CNC 02 Nos. CT3 CNC 02 Nos. CT6 CNC |
P-103/5 |
58 |
22/03/13 |
Deep Vein Thrombosis Pump (DVT Pump) |
Cosmotec Medicaments (P) Ltd. |
1625/CNC/CARD/12-13 |
01 No. CT2 CNC 01 No. CT3 CNC |
P-104/5 |
59 |
28/03/13 |
ECG Machine Pagewriter TC50 |
DeAsh Trade-Net (P) Ltd., |
1794/CNC/CARD/12-13 |
01 No. CT3 CNC 01 No. CT6 CNC (11,12) |
P-105/5
|
60 |
28/03/13 |
3D CARTO ELECTROANATOMICAL EP AND MAPPING SYSTEM |
Johnson & Johnson Ltd., |
1871/CNC/CARD/12-13
|
01No. Cath Lab CNC (44) |
P-106/5 |
61 |
28/03/13 |
Optical Coherence Tomography (OCT) C7-XR System |
St Jude Medical India (P) Ltd. |
1875/CNC/CARD/12-13 |
01No. Cath Lab CNC (22)
|
P-107/5 |
62 |
30/03/13 |
Dual Chamber Temporary Pacemaker PACE T20 |
J. Mitra & Bros., |
1777/CNC/CARD/12-13 |
05Nos. Cath Lab CNC
|
P-108/5 |
63 |
30/03/13 |
Single Chamber Temporary Pacemaker Pace T10 |
J. Mitra & Bros., |
1782/CNC/CARD/12-13 |
05Nos. Cath Lab CNC
|
P-109/5 |
64 |
30/03/13 |
Portable C-Arm DSA
|
Philips Electronics (I) Ltd., |
1774/CNC/CARD/12-13 |
01 No. CT2 CNC HANDED OVER TO CARDIAC-RADIOLOGY |
P-110/5
|
65 |
27/05/13 |
90217-A Untralite Ambulatory Blood Pressure Monitor with 1 Analyzer |
M/s Spacelabs Healthcare |
100-14/CNC/CARD/12-13 |
05Nos. Holter Lab. CNC (ABPS 36-40) |
P-111/5 |
66 |
24/06/13 |
Terufusion Syringe Pump 220V ( TE 331NW3S) |
M/s J. Mitra & Bros. |
100-27/CNC/CTVS/ CARD/12-13 |
15Nos. CCU CNC 10Nos. CT3 CNC 15Nos CT6 CNC |
P-112/5 |
67 |
02/07/13 |
Advanced Intensive Care Ventilators ICU Model:- GE ENGSTROM CARESTATION |
M/s Wipro GE Healthcare (P) Ltd |
100-38/CNC/CARD/12-13 |
02Nos. CCU CNC 02Nos CT6 CNC |
P-113/5 |
68 |
09/07/13 |
INTRA AORTIC BALLOON PUMP ( IABP- CS100) |
M/s Datascope Corpn.
Local:- J Mitra & Bros |
100-25/CNC/CARD/12-13 |
02Nos. Cath Lab CNC (6, 9) |
P-114/5 |
69 |
16/07/13 |
Portable CX50 Compact Extreem Ultrasound System S.N. US 31302098 |
Philips Electronics (I) Ltd., |
100-16/CNC/CARD/12-13 |
01No CT6 CNC (8) |
P-115/5 |
70 |
19/07/13 |
Hemodynamic Recorder Model:- GE MAC Lab. |
M/s Wipro GE Healthcare (P) Ltd |
100-52/CNC/CARD/12-13 |
02Nos. Cath Lab CNC (27, 29)
|
P-116/5 |
71 |
31/03/14 |
Forced Air Warmer Unit Mistral –Air ® Plus |
M/s Hansraj Healthcare (P) Ltd. |
1647/CNC/CARD/13-14 |
03Nos. CT-6 CNC 01No. Cath Lab ?2 Nos |
P-117/5 |
72 |
17/06/14 |
Syringe Infusion Pump Model WIT-301A |
Surya Dev Healthcare |
262/CNC/CARD/14-15 |
10Nos. CCU CNC 05Nos. CT3 CNC 05Nos CT6 CNC |
P-118/5 |
73 |
14/07/14 |
Philips IntelliVue MX 800 Patient Monitor |
M/s Philips Healthcare |
100-15/CNC/CARD/ 12-13 |
21Nos. CCU CNC ( 01No. Holter/TMT Lab CNC) 14Nos. CT6 CNC |
P-119/5 |
74 |
11/02/15 |
External Defibrillator, Monitor with Transcutaneous Pacer Phillips |
DeAsh Trade-Net (P) Ltd. |
474/CNC/CARD/14-15 |
02Nos. CT2 CCU, CNC |
P-120/5 |
75 |
11/02/15 |
Philips ECG Machine PAGEWRITER TC50 |
DeAsh Trade-Net (P) Ltd. |
844/CNC/14-15 |
01No. CT2 CCU, CNC |
P-121/5 |
76 |
11/05/15 |
Infant Warmer Make Phoenix Model:- CIC101 |
Phoenix Medical Systems (P) Ltd. |
1338/CNC/14-15 |
04Nos. CT6 CNC |
P-122/5 |
77 |
10/07/15
23/07/15 |
Portable 2D Echocardiography Color Doppler System Model:- GE VIVID Q S.N. 055659
Portable Card 01No. Storage Device (3TB HDD) 01No. |
Wipro GE
Wipro GE |
100-31/CNC/CARD/14-15
1599/CNC/14-15 |
01No. CT2 CCU
CT2 CCU |
P-123/5
P-123/5 |
78 |
21/07/15
17/07/15 |
Fabian HFO Ventilator
Essential Accessories for Fabian HFO Ventilator |
Acutronics Medical Systems
Phoenix Medical Systems |
100-10/ CNC/CARD/14-15
1598/CNC/CARD/14-15 |
01No. CT6 CNC
CT6 CNC |
P-124/5
P-124/5 |
79 |
26/08/15
28/08/15 |
Cath Lab Model:-INFX 8000V/G1 Make: Toshiba-Main Unit
Accessories |
Erbis Engineering Co. Ltd.
Erbis Engineering Co. Ltd |
100-26/CNC/CARD/14-15
1419/CNC/CARD/14-15 |
Cath Lab, CNC HANDED OVER TO CARDIAC-RADIOLOGY
Cath Lab, CNC |
P-125/5
P-125/5 |
80 |
04/01/16 |
Portable 2D Echocardiography Color Doppler System With Intracardiac Echo Facility CX50 Compact Xtreme Ultrasound System S.N. SG 91500055 |
Philips Medical Systems |
100-04/CNC/CARD/14-15/ST |
01No.ECHO lab, CNC |
P-126/5 |
81 |
03/03/16 |
BFW Head Light |
Asia Pacipic Export/J. Mitra & Bros. |
100-13/CNC/CARD/14-15/ST |
01No. Cath Lab , CNC |
P-127/5 |
82 |
04/07/16 |
EPIQ CV Ultrasound System S.N. US316B0387 |
Philips Medical System |
100-28/CNC/CARD/14-15/AT |
01No.ECHO lab, CNC |
P-128/5 |
83 |
27/07/16 |
Syringe Pump M- AP-12-DL Make SSMED |
S.S. Medical Systems (I) Pvt. Ltd. |
188/CNC/CARD/16-17/ST |
04Nos. CT2 CCU, CNC 03Nos. CT3, CNC 03Nos. CT6, CNC 03Nos. Cath Lab. CNC |
P-129/5 |
84 |
03/10/16 |
New Holter Recorder for Holter Lab. |
Schiller Healthcare |
858/CNC/CARD/16-17 |
10Nos. Holter Lab, CNC |
P-130/5 |
85 |
02/12/16
|
Portable ECG Machine Model-3312B |
Taurus Healthcare (P) Ltd. |
1047/CNC/CARD/16-17 |
02Nos. ECG Lab CT-6 02Nos. ECG Lab OPD |
P-131/5 |
86 |
31/3/17
|
External Defibrillator, with Transcutaneous Pacer
|
Medina 2500 |
1393/CNC/CARD/ 16-17 |
01Nos. CT2 01Nos. CT3 01Nos. CT6 01Nos. TMT 01Nos. Cath Lab |
P-132/5 |
List of Senior Residents, Department of Cardiology
Batch – July 2019
S. No. Name of Resident
1. Dr. Sumit Kumar
2. Dr. Asharam Panda
3. Dr. Lamk Kadiyani
4. Dr. Jeedigunta Mahidhar
Batch - January 2020
S. No. Name of Resident
1. Dr. Nayani Balbir Singh Makkar
2. Dr. Sataroopa Mihsra
3. Dr. Vibhav Sharma
4. Dr. Pavan Kumar Reddy Velpula
Batch – July 2020
S. No. Name of Resident
1. Dr. Praveen M.
2. Dr. Manjit Mahendran
3. Dr. Mukesh Dhillon
4. Dr. Devesh Kumar
5. Dr. Ankur Handa
6. Dr. Kshitij Prasad
Batch – January 2021
S. No. Name of Resident
1. Dr. Mohsin Raj
2. Dr. Sai Durga
3. Dr. Gorav Sharma
4. Dr. Pramod
5. Dr. Charu
6. Dr. Chandan Sharma
7. Dr. Shatanik Sarkar
Batch – July 2021
S. No. Name of Resident
1. Dr. Goutam Kintada
2. Dr. Aswin K Pius
3. Dr. Shitij
Batch – January 2022
S. No. Name of Resident
1. Dr. Nabeel Faisal V.
2. Dr. Lydia James George
3. Dr. Abhinav Jain
4. Dr. Avishkar Agrawal
5. Dr. Relangi Hitesh Srinavas Krishna
6. Dr. Souvik Sardar
7. Dr. Neha Chopra
8. Dr. Akkineni Krishna Prasad
All India Institute of Medical Sciences
Ansari Nagar, New Delhi - 110029
Board Number : +91-11-26588500 / 26588700
Fax : +91-11-26588663 / 26588641